The DSH Drain Hose Coupler connects sections of DSH drain hose to the AC unit’s drain outlet, creating a secure joint that supports effective condensate management.
SKU
DSH-14C
Categories Condensate Management, Insulated Drain Hose & Accessories
Tag drain hose coupler
Brand: DSH-UP
DSH-14C Hose to A/C attached hose coupler




SKU
DSH-14C
Categories Condensate Management, Insulated Drain Hose & Accessories
Tag drain hose coupler
Brand: DSH-UP
DSH-14C Hose to A/C attached hose coupler
The DSH Drain Hose Coupler connects DSH hoses to the AC unit’s drain outlet, enabling secure, leak-free joints. Ideal with the DSH-Up Kit, it simplifies installation and supports efficient condensate management.
- To join with A/C’s unit drain hose. Need to confirm size of A/C unit’s drain hose.
- Caution: DSH series must be used indoor.
- Cut drain hose in right angle, and completely remove any dust, oil and trash.
- Use cement/glue for PVC pipe use and insert drain hose/pipe fully into accessory fitting to avoid any problems such as water leakage.
- Do not bend drain hose by a radius or less than three times the outer diameter.
- Do not slack drain hose when installing (Need slope for water flow).
- Use drain hose accessories exclusively with Inaba Denko drain hoses. Use of these products in combination with any other brand will invalidate warranty.
- Do not use cement/glue for PVC pipe connection between drain hose (DH/DHQ) & coupler (DSH014H/DSH014J). Insert drain hoses, accessory fittings and secure with tape.
Code No. | Item No. | Compliant drain hose | Pcs/Pkg |
---|---|---|---|
C 08200 | DSH-14C | DSH-14 | 100 |
Caution:
- DSH series must be used indoors.
- Cut drain hose in right angle, and completely remove any dust, oil and trash.
- Use cement/glue for PVC pipe se and insert drain hose/pipe fully into acessory fitting to avoid any problems such as water leakage.
- Do not bend drain hose by a radius or less than three times the diameter.
- Do not slack drain hose when installing (Need slope for water flow).
- Use drain hose accessories exclusively with Inaba Denko drain hoses. Use of these products in combination with any other brand will invalidate warranty.
- Do not use coment/glue for PVC pipe connection between drain hose (DH/DHQ) & coupler (DSH-14H/DSH14J) insert drain hoses, accessory fittings and secure with tape.
Q. Are there any proven cases of installation?
A . With sales in Japan and the world, we have about 600,000 units of actual installation.
Q. Can I use DSH-UP for equipment besides air-conditioning units?
A . DSH-UP is designed to work as an air conditioning condensate drain hose only and should not be used outside of its intended purpose.
Q. Can DSH-UP be used outdoors?
A . It is specialized for indoor use. Please do not use it outside.
Q. When connecting the DSH-UP coupler to a PVC pipe, is it okay to use an adhesive instead of a metal band to make the connection?
A . Please do not use adhesive. Only use the metal hose band for connections.
Q. Are the DSH-UP couplers and other parts included in the kit also sold separately?
A . No, the parts must be purchased as part of the kit.
Q. What should I do about condensation around the product?
A . Depending on the surroundings, insulation can be wrapped around the hose and coupler as a countermeasure to condensation.
You May Also Be Interested In

DSH-Up ER Elbow Type
The Drain Hose Kit (Elbow Type) ensures smooth, kink-free drainage in tight or angled spaces....

DSH-Up E Elbow Type
The DSH-Up Elbow Type is a thermal insulated drain-up hose kit for indoor AC units...

DSH-Up S Straight Type
The DSH-Up Straight Type is a thermal insulated drain-up hose kit for indoor AC units...

DSH-14J Hose to coupler extension
The DSH Hose-to-Hose Coupler Extension connects DSH to standard Drain Hose or DHQ, offering a...